High shear emulsifier troubleshooting method

1. The vacuum of the high shear emulsifier cannot be established:

1. Check if the vacuum pump is running normally;

2. Check if the vacuum pipe is sealed and the seal ring is leaking;

3. Check if the vacuum valve is open;

4. Check if the vacuum pump is filled or if the vacuum pump tank is filled with water;

5. Check if the direction of rotation of the vacuum pump is correct.

Second, the homogenization and stirring motor of the high shear emulsifier can not be started normally:

1. Check if the power supply is normal, and if there is any leakage of power on the power line;

2. Check if the motor fan blades are running normally and the motor is faulty.

3. Check whether the homogenizing head is normal, and whether there is any foreign matter stuck to the homogenizing head;

4. Check if the electric control cabinet relay jumps out and the limit switch is released.

Third, the high-shear emulsifier stirring scraping wall knife can not scratch the wall:

1. Check if the stirring slurry is eccentric;

2. Check if the scraper is seriously worn;

3. Check if the scraping wall is stuck with foreign matter and cannot be flexibly rotated.